Carrier nomenclature chart

View and Download Carrier 50TFF007-014 product data online. Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz. 50TFF007-014 air conditioner pdf manual download. ... Model number nomenclature LEGEND *Refer to 50TFF ordering data or contact your local Carrier representa- tive for 50TFF FIOP code table. — Aluminum ...

MODEL NUMBER NOMENCLATURE CH14 N 018 14 SEER Heat Pump with Puron Refrigerant Electrical Supply N – 208/230–60–1 Nominal Capacity 018 –1–1/2Tons 024 –2Tons 030 –2–1/2Tons 036 –3Tons 042 –3–1/2Tons 048 –4Tons 060 –5Tons B B–Puron B Variations A Series 00G Variations 00G – Dense Grille Use of the AHRI Certified TM ... This manual is also suitable for: View and Download Carrier Performance 50VT product data online. Single-Packaged Heat Pump Units with Puron (R-410A) Refrigerant Single-And Three-Phase 2 to 5 Nominal Tons (Sizes 024-060). Performance 50VT heat pump pdf manual download.

Did you know?

30 to 100 Nominal Tons. 48P2 – Vertical CV/SAV. 48P3 – Vertical VAV. 48P4 – Horizontal CV/SAV. 48P5 – Horizontal VAV. Carrier P Series rooftop units are pre-wired and factory-tested in both cooling and heating modes. All models feature an industrial grade cabinet with fully hinged access panels.Air Conditioner Carrier 38CK (M) Installation And Start-Up Instructions Manual. 38ck seriessplit-system air conditioner (6 pages) Air Conditioner Carrier 38CKX Product Data. 50 hz sizes 024 thru 060 (12 pages) Air Conditioner Carrier 38CKX Installation And Start-Up Instructions Manual.MODEL NUMBER NOMENCLATURE CH14 N 018 14 SEER Heat Pump with Puron Refrigerant Electrical Supply N – 208/230–60–1 Nominal Capacity 018 –1–1/2Tons 024 –2Tons 030 –2–1/2Tons 036 –3Tons 042 –3–1/2Tons 048 –4Tons 060 –5Tons B B–Puron B Variations A Series 00G Variations 00G – Dense Grille Use of the AHRI Certified TM ...

CARRIER MODEL AND SERIAL NUMBER, HOW TO TELL DATE AND SIZE. Have a few carrier units need to know age and tonnage, M# 48TFD005---511--. S# 1702640092. M# 48TFE008---511--. S#0402621477. M# 48TJF016---58IYA. S#2602F63529. Appreciate any help or any links to a carrier site that i can use in the future to identify units.Overview. This compact ductless model is simple to install, only wires and piping need to run between the indoor and outdoor units. The 38MARB model also features premium energy efficiencies of 28.1 SEER2 and 12.4 HSPF2 making it a great choice for retrofit applications. View Technical Specification. Type.028 units, and one size for all others].)<br /> The contractor can order and<br /> install the roof curb early in the construction<br /> stage, before decisions on<br />Models. 48TM016-028; Contents. Installation, Start-Up and Service Instructions. CONTENTS; SAFETY CONSIDERATIONS; 48TM016-028 Single-Package Rooftop Units Electric Cooling/Gas HeatingFEATURES AND BENEFITS S Single- stage cooling capacity control on 04 to 07 models, 2- stage cooling capacity control on 08 to 14 models S SEER up to 15.6, EER up to 13.0 S IEER’s up to 13.0 with single speed indoor fan motor, and up to 14.3 with SAVt (Staged Air Volume) 2- speed/VFD indoor fan motor system S Exclusive non- corrosive composite condensate pan in accordance with ASHRAE 62 ...

Carrier heat pumps with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 25HPB6 has been designed utilizing Carrier’s non--ozone depleting Puron refrigerant. This product has been designed and manufactured to meet Energy Starr criteria for energy efficiency when matched with appropriate coil ...30 to 100 Nominal Tons. 48P2 - Vertical CV/SAV. 48P3 - Vertical VAV. 48P4 - Horizontal CV/SAV. 48P5 - Horizontal VAV. Carrier P Series rooftop units are pre-wired and factory-tested in both cooling and heating modes. All models feature an industrial grade cabinet with fully hinged access panels.For Air Conditioner systems, the chart below shows when an application is considered Long Line. Note: See Residential Piping and Long Line Guideline for details Table 3 – Refrigerant Charge Adjustments Liquid Line Size Puron Charge oz/ft (g/m) 3/8 0.60 (17.74) (Factory charge for lineset = 9 oz / 266.16 g) 5/16 0.40 (11.83) 1/4 0.27 (7.98) ….

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Carrier nomenclature chart. Possible cause: Not clear carrier nomenclature chart.

In today’s globalized world, the transportation of goods is essential for the functioning of economies. One crucial aspect of this transportation industry is bulk liquid tanker carriers.Model number nomenclature 40RM-016SD B5 0 1 ED 40RM Commercial Packaged Air Handler Cooling Coil -Direct Expansion S Chilled Water Nominal Capacity Tons (kW) 007 6 (21) 016 15 (52) Mobile carriers play a crucial role in our daily lives, providing us with the means to stay connected wherever we go. With numerous options available, it can be overwhelming to choose the right mobile carrier that suits our needs.

Carrier 48TM016-028 specifications. Download. <. >. Manufa cturer res erves the right to discon tinue, or chang e at any time, specificat ions or designs witho ut notic e and wit hout inc urring obligati ons. Catalog No. 04-5348 0016- 01 Pr inted in U.S.A. Form 48T M-4SI Pg 1 3-06 Replace s: 48T M-3SI. Book 1 4.View and Download Carrier 50TFF007-014 product data online. Single-Package Rooftop Units Electric Cooling with Electric Heat Option 50 Hz. 50TFF007-014 air conditioner pdf …Mobile carriers play a crucial role in our daily lives, providing us with the means to stay connected wherever we go. With numerous options available, it can be overwhelming to choose the right mobile carrier that suits our needs.

lux nails sioux falls Jul 28, 2020 · The most common way to to determine the carrier ac age is through the serial number. In the above style, the determining factor is having a letter in the middle of the serial number. The first two digits are the week of manufacturer. The second set of digits are the year of manufacture. Therefore, this unit was manufactured in 2019 in week 2. circus conceptsderik trocke board by Carrier puts all your connec-tions and troubleshooting points in one convenient place, standard. Most low voltage connections are made to the same board and make it easy to find what you're looking for and easy to access it. Carrier rooftops have high and low pressure switches, a filter drier, and 2-in. (51 mm) standard filters.liquid lines, charge adjustments are required per the chart above. ChargingFormula: [(Lineset oz/ft x total length) – (factory charge for lineset)] = charge adjustment Example 1:System has 15 ft of line set using existing 1/4“ liquid line. What charge adjustment is required? Formula: (.27 oz/ft x 15ft) – (9 oz) = (-4.95) oz. jaculi dnd 5e units matched with Carrier’s 40RU series indoor air handlers offer a wide variety of options for your HVAC application needs. Whether it’s first cost with the 38AU single compressor models or superior part load performance from the two compressor models, this series is designed for long, dependable operation as a rooftop or on-the-ground ... Carrier’s Air Conditioners with Puronr refrigerant provide a collection of features unmatched by any other family of equipment. The 24ACC4 has been designed utilizing Carrier’s non--ozone depleting Puron refrigerant. NOTE: Ratings contained in this document are subject to change at any time. Always refer to the AHRI directory 5x8 plywooddunn funeral home eddyville ky obituariescullman county jail inmates mugshots Carrier 48TJD Series Installation, Start-Up And Service Instructions Manual (53 pages) Single-Package Rooftop Heating/Cooling Units. Brand: Carrier | Category: Air Conditioner | Size: 1.69 MB. Table of Contents. Table of Contents. 1. 15 day forecast fayetteville nc New direct drive - EcoBlue™ Technology indoor fan system uses Vane Axial fan design & electronically commutated motor. Single-stage cooling capacity 04-06 models, two-stage on 07 models. SEERs up to 14.0, IEER of 15.2. Cooling operating range up to 115 °F (46°C) and down to 40°F (4°C) using winter start kit. model number nomenclature outdoor unit 38 ma r b q 36 -- 3 38 = outdoor unit ma = model voltage 1=115-1-60 3=208/230-1-60 system type r = outdoor maximum number of fan coil units that can be connected to the outdoor unit b = 1:1 unit type q = heat pump nominal capacity 09 - 3/4 ton 12 - 1 ton 18 - 1-1/2 tons 24 - 2 tons 30 - 2-1/2 tons 36 - 3 ... reidout ratingsclosest whataburger restauranttoltrazuril tractor supply Model 38BRC Energy-Efficient Air. Conditioner incorporates innovative. technology to provide quiet, reliable. cooling performance. Built into these. units are the features most desired by. homeowners today, including SEER. ratings of at least 12.0 when used with. specific Carrier indoor sections.Carrier 48TF006 Pdf User Manuals. View online or download Carrier 48TF006 Installation, Start-Up And Service Instructions Manual, Wiring Diagrams, ... 3 Ton Unit Charging Chart. 40. 4 Ton Unit Charging Chart. 40. Cooling Charging Chart, 48TF004. 40. Cooling Charging Chart, 48TF005. 40. 5 Ton Unit Charging Chart. 41.